• Volume/Page
  • Keyword
  • DOI
  • Citation
  • Advanced
   
 
 
 

You are not logged in You are not logged in to this journal. Log In

Noise Control Eng. J. 60, 1, pp. 121-123 (2012)

Uncertainty minimization in LAeqT measurements

Rufin Makarewicz

Institute of Acoustics, A. Mickiewicz University, 61-614 Poznań, Umultowska 85, POLAND; email: makaaku@amu.edu.pl.

Roman Gołębiewski

Institute of Acoustics, A.Mickiewicz University, 61-614 Poznań, Umultowska 85, POLAND,

Full Text: Download PDF | Buy PDF (US$4) | View Cart
Usually, the time-term average sound level, L, is not directly measured but calculated from the measured sound exposure levels. Variance of L1,….., Ln quantifies the uncertainty of noise measurements. In any case, a decrease in the variance means an increase in the quality of measurements. This paper shows how to decrease the variance of L1,….., Ln.

© 2012 Institute of Noise Control Engineering

KEYWORDS and PACS

PACS

  • 43.50.Rq

    Environmental noise, measurement, analysis, statistical characteristics

  • 43.50.Yw

    Instrumentation and techniques for noise measurement and analysis

ARTICLE DATA

History
Received May 26 2011
Accepted Dec 21 2011

PUBLICATION DATA

ISSN

0736-2501 (print)  

For access to fully linked references, you need to log in.